The NDM5-1600 series of moulded case circuit breakers (referred to as circuit breakers) have a rated insulation voltage of 1000V and apply to circuits with the AC 50Hz/60Hz, the rated working voltageAC380/400/415V、AC500V、AC660/690V、AC800V,Vand rated working current (800A to 1250A). The circuit breakers are used for distributing power while protect the overload, short circuit and under-voltage (with a under-voltage release) of lines and power units as well as the infrequent starting, braking, overload and short circuit of motors. Each voltage level and short-circuit section capacity of the circuit breaker can be connected with the lower incoming line.(Except AC800V )
Normal Working Environment of Circuit Breaker 1) The altitude of the installation site doesn’t exceed 2,500m. See the “High-altitude DeratingFactor Table of Circuit Breaker” for the derating factor at the altitude; 2) The ambient temperature is -35℃ ~ + 70℃; the average within 24 h shall not be more than+35℃. If the ambient temperature is higher than +40℃, the user needs to reduce the capacity.See the “Derating Factor Table of Temperature Change for the Circuit Breaker” for the derating factor; 3) Its relative humidity at an ambient temperature of +40℃ should not exceed 50%. A higherrelative humidity is allowed at a lower temperature. For example, the relative humidity at20℃ can reach 90%; for frost due to temperature change, the corresponding measuresshould be taken; 4) The product can withstand the effects of wet air, salt mist, oil mist and mould; 5) The installation category of the circuit breaker connected to the main loop is: Category Ⅲ (power distribution and control level), The installation category of the circuit breaker notconnected to the main loop is: Category Ⅱ (load level); 6) The pollution level is Level 3; 7) Degree of protection: IP 20; 8) The product should be installed in places that are free from explosive media, media corrosiveto metal, insulation damaging gas, and conductive dust, which should be also avoided fromsnow and rain; 9) In case of stricter user conditions than the above description, negotiate with the manufacturer.
1. Applicable Scope and Purpose The NDQ3-400 P-grade ATSE are applicable for sites with the AC voltage below AC380V.AC400V.AC415V and the rated frequency of 50Hz. This product complies with the GB14048.1-2012 and GB/T14048.11-2016 standards i...
1.Product Overview: NDB2F-125 meter external circuit breaker is specially developes to solve the problem of the prepaid meter external circuit breaker failing to be closed automatically. The product adopts a miniature circuit breaker with the shor...
NDB6AZ-63H series products are mainly used in telecommunications equipment rooms or communication cabinets, as isolation, short circuit and overload protection for cabinets, equipment rooms or downstream subscriber lines.
The NDM3A-630 molded case circuit breaker (hereinafter referred to as circuit breaker) appliesto infrequent switching of circuits with the AC 50/60Hz, the working voltage of AC1000V and working current of 630A as well as infrequent motor startin...