Available CertificationsCE
Availability depends on model and configuration.
The NDM3A-630 molded case circuit breaker (hereinafter referred to as circuit breaker) appliesto infrequent switching of circuits with the AC 50/60Hz, the working voltage of AC1000V and working current of 630A as well as infrequent motor starting. With the overload, short circuit and undervoltage protection functions, the circuit breaker can protect lines and power equipment from damage.
Normal Working Environment 1)The altitude of the installation site doesn’t exceed 2,500m. See the “High-altitude DeratingFactor Table of Circuit Breaker” for the derating factor at the altitude; 2)The ambient temperature is -35℃ ~ + 70℃; the average within 24 h shall not be morethan +35℃. If the ambient temperature is higher than +40℃, the user needs to reduce thecapacity. See the “Derating Factor Table of Temperature Change for the Circuit Breaker”for the derating factor; 3)Its relative humidity at an ambient temperature of +40℃ should not exceed 50%. A higherrelative humidity is allowed at a lower temperature. For example, the relative humidity at20℃ can reach 90%; for frost due to temperature change, the corresponding measuresshould be taken; 4)The product can withstand the effects of wet air, salt mist, oil mist and mould; 5)The installation category of the circuit breaker connected to the main loop is: Category Ⅲ (power distribution and control level), The installation category of the circuit breaker notconnected to the main loop is: Category Ⅱ (load level); 6)The pollution level is Level 3; 7)The product should be installed in places that are free from explosive media, mediacorrosive to metal, insulation damaging gas, and conductive dust, which should be alsoavoided from snow and rain; 8)In case of stricter user conditions than the above description, negotiate with themanufacturer.
NDB1LE-100 is a compact residual-current circuit breaker for low-voltage terminal distribution. It combines overload, short-circuit, earth-leakage and isolation protection in one DIN-rail device. Typical configuration only. Final ratings are conf...
Gemeral SVM5H series of moulded case circuit breaker is supplied with rated insulating voltage 1150V and used for circuit of A.C. 50Hz, rated operating voltage AC 1140V. (or below), rated operating current up to 630A for infrequent changing over a...
Key Specifications/ Special Features: ACB with multiple protection function in do high precise of selective protection at the same time, also can avoid unnecessary suddenpower failure, improve the reliability, security, power supply system. Part N...