SVM5H-400H/R MCCB 1 000 V CA

SVM5H-400H/R  1000VAC MCCB(images 1)

Gemeral

SVM5H series of moulded case circuit breaker is supplied with rated insulating voltage 1150V and used for circuit of A.C. 50Hz, rated operating voltage AC 1140V. (or below), rated operating current up to 630A for infrequent changing over and starting of the motors.

Products are widely used in new energy, photovoltaic (string type), electric power, industrial control, real estate, power supply, telecommunications, rail transit and other industries.

Equiped with the protection devices for over-current, short circuit and u ndervoltage, the products are capable of preventing damage of circuits and supply units. The products conforms to GB/T14048.2, IEC60947-2 stardands.

Normal Operating Conditions                                            

Altitude: ≤2000m  

Installation height 2000m ~ 5000m can be specially customized. The product needs to reduce the capacity to use.

Pollution Degree: 3 according to IEC 60947-1

Ambient Temp. (operating): -5 to 40 ℃

For the working conditions of -40~-5℃ ambient temperature, please inform us when ordering.

When the ambient temperature is higher than 40 ° C, the product should be used at reduced capacity.

Ambient Temp. (storage): -40 to 70 ℃

The average ambient temp. in 24 hours cannot exceed 35 ℃.

The relative humidity cannot exceed 50% @+40 ℃. A lower temperature can have a higher humidity. The relative humidity can reach 90% at 20 ℃, and corresponding measures should be taken for the condensation frost caused by the temperature change.

Model Description of MCCB

SVM5H-400H/R  1000VAC MCCB(images 2)

Characteristics                                                            

Poles3P
Frequency50 Hz
Rated Current (In)250, 280, 315, 320, 350, 400
Rated Insulation Voltage Vi1150 V AC
Rated Impulse Withstand Voltage (Uimp)8kV
Rated Operational Voltage (Ue)AC415VAC500/550 /690/600VAC800VAC1000 /1140V
Breaking Capacity CodeHRHRHRHR
Limiting Short-circuit Breaking Capacity Icu85100506036.5501015
Operating Short-circuit Breaking Capacity Ics85100506036.5501015
Mechanical Life10000 cycles
Electrical Life1000 cycles1000 cycles1000 cycles700 cycles
Ambient Temperature-35℃~+70℃
AccessoryShunt release, auxiliary device, alarm device, manual operating mechanism, electric operating mechanism
Dimensions (L*W*H)250*182*165mm
LAST : SUIVANT :

Recommandations connexes

  • NDM2E-800(M,H)

    956

    1. Applicable Scope and Purpose of Circuit Breaker The NDM2E-800 series of electronic molded case circuit breakers (hereinafter referred to as circuit breakers) apply to infrequent switching of circuits with the AC 50Hz, the working voltage of A...

    Voir les détails
  • NDC1(Z)-38 AC Contactor with AC or DC Coil

    1566

    NDC1(Z)-38 AC Contactor, which used in 50Hz(60Hz) AC circuit with the rated voltage of 1000V. It is used in AC-3 type, with the rated working voltage of 415V and rated working current of 38A, to realize distant connection and disconnection of the ...

    Voir les détails
  • NDG3V-250-800 Isolating Switch

    1222

    Applications: The NDG3V-250~800 series switch-disconnectors are applicable to electric systems with a rated voltage up to DC 1500V and a rated current up to 800A. It can be used for infrequent close and open, it provides isolation and breaking ...

    Voir les détails
  • NDB2F-125 MCB miniature circuit breaker

    987

    1.Product Overview: NDB2F-125 meter external circuit breaker is specially developes to solve the problem of the prepaid meter external circuit breaker failing to be closed automatically. The product adopts a miniature circuit breaker with the shor...

    Voir les détails
En savoir plus !

Liste des produits disponibles
Liste des produits disponibles Envoyer une demande de renseignements sur les produits ci-dessus