{"id":1202,"date":"2024-04-08T16:15:27","date_gmt":"2024-04-08T08:15:27","guid":{"rendered":"http:\/\/www.sovinelec.com\/?p=1202"},"modified":"2024-04-08T16:15:29","modified_gmt":"2024-04-08T08:15:29","slug":"rcbo-ndb1le-63-c63-type-a","status":"publish","type":"post","link":"https:\/\/www.sovinelec.com\/ru\/2024\/04\/08\/rcbo-ndb1le-63-c63-type-a\/","title":{"rendered":"RCBO NDB1LE-63 C63, \u0442\u0438\u043f A"},"content":{"rendered":"<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"http:\/\/www.sovinelec.com\/wp-content\/uploads\/2024\/04\/NDB1LE-63-C63-Type-A-1024x1024.png\" alt=\"\" class=\"wp-image-1203\" srcset=\"https:\/\/www.sovinelec.com\/wp-content\/uploads\/2024\/04\/NDB1LE-63-C63-Type-A-1024x1024.png 1024w, https:\/\/www.sovinelec.com\/wp-content\/uploads\/2024\/04\/NDB1LE-63-C63-Type-A-300x300.png 300w, https:\/\/www.sovinelec.com\/wp-content\/uploads\/2024\/04\/NDB1LE-63-C63-Type-A-150x150.png 150w, https:\/\/www.sovinelec.com\/wp-content\/uploads\/2024\/04\/NDB1LE-63-C63-Type-A-768x768.png 768w, https:\/\/www.sovinelec.com\/wp-content\/uploads\/2024\/04\/NDB1LE-63-C63-Type-A-1536x1536.png 1536w, https:\/\/www.sovinelec.com\/wp-content\/uploads\/2024\/04\/NDB1LE-63-C63-Type-A-2048x2048.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Application Scope and Purpose<\/strong><br>\u25cf Short-circuit protection<br>\u25cf Overload protection<br>\u25cf Current leakage protection<br>\u25cf Isolation protection<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The NDB1LE-63 series of residual current action circuit breakers provide the ground leakage, direct or indirect electric shock by human body and other faults protection, which are applicable to the low -voltage terminal distribution in the industry, civil buildings, energy, communication, infrastructure and other fields.  <\/p>\n\n\n\n<ol class=\"wp-block-list\"><\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Main Technical Parameters<\/strong><br>\u25cf Electrical parameters<br>\u25cf Frequency: 50\/60Hz<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u25cf Rated working voltage: AC230V\/240V (1PN(One protection pole , N pole continued conducting), 2P, C400V\/415V(3P, 3PN(Three protection pole , N pole continued conducting), 4P) <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u25cf Rated impulse withstand voltage: 4kV<br>\u25cf Rated insulation voltage: 500V<br>\u25cf Residual operating current type: A, AC<br>\u25cf Instantaneous tripping characteristics: Type B, C, D<br>\u25cf Rated working current: 1A, 2A, 3A, 4A, 5A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A<br>\u25cf Rated short breaking capability(Icn): 6kA<br>\u25cf Rated operating breaking capability(Ics): 6kA<br>\u25cf Rated residual operating current: 30mA, 50mA, 100mA, 300mA<br>\u25cf Mechanical life: 20,000 times<br>\u25cf Electrical life: 10,000 times<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u25cf Isolating function<br>\u25cf Leakage visualization<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u25cf Protection class<br> Protection class of the circuit breaker body: IP20<br> To be installed in the distribution box: IP40<\/p>\n\n\n\n<ol class=\"wp-block-list\" start=\"4\"><\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Normal Working Environment<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Altitude: \u22642000m, In case of use at the higher altitude, refer to the requirements of the miniature circuit breaker for derating. Refer to GB\/T20645 \u201cSpecific Environmental Condition &#8211; T2020.12.18echnical Requirements of Low-voltage Apparatuses for Plateau\u201d. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u25cf Pollution level: 3<br>\u25cf Using ambient temperature: -25\u2103~+60\u2103<br>\u25cf Wet heat resistance: The humidity should be not more than 95% at 55\u2103<br>\u25cf Storage ambient temperature: -40\u2103~+80\u2103<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u25cf The product can withstand the effects of salt mist and oil mist<br>\u25cf The product can be disposed in places that are free from explosive media, media corrosive to metal, insulation damaging gas, and conductive dust <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u25cf The product should be installed free from snow and rain<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Packaging and Storage<\/strong><br>Maximum packaging quantity: \uff081A\uff5e32A\uff081PN\uff09 product: 5 pieces\/box, 1A\uff5e32A\uff082P\uff09 product: 4 pieces\/box, 1A\uff5e32A\uff083P\/3PN\/4P\uff09product: 2 pieces\/box\uff1b40A\uff5e63A\uff081PN\uff09 product: 4 pieces\/box, 40A\uff5e63A\uff082P\uff09 product: 3 pieces\/box, 40A\uff5e63A\uff083P\/3PN\uff09product: 2 pieces\/box, 40A\uff5e63A (4P) product: 1 piece\/box).. The packaged products should be stored in a warehouse with the air ventilation and the relative humidity no more than 80% and the temperature between -40\u2103 and +80\u2103. No acidic, alkaline or other corrosive gas exists in the ambient air in the warehouse. Under the above conditions, the storage period shall be no more than three years since the manufacturing date.<\/p>\n\n\n\n<ol class=\"wp-block-list\" start=\"9\"><\/ol>","protected":false},"excerpt":{"rendered":"<p>Application Scope and Purpose\u25cf Short-circuit protection [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1225,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false,"_geo_short_summary":"","_geo_structured_desc":"","_geo_faqs":"","_geo_key_points":"","_geo_target_audience":"","_geo_content_type":"","_geo_last_modified":"","_geo_version":0,"themepark_seo_title":"","themepark_seo_description":"The NDB1LE-63 series of residual current action circuit breakers provide the ground leakage, direct or indirect electric shock by human body and other faults protection, which are applicable to the low -voltage terminal distribution in the industry, civil buildings, energy, communication, infrastructure and other fields. ","footnotes":""},"categories":[5,19],"tags":[27,25,29,26,30],"class_list":["post-1202","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-znxx","category-new-energy-product","tag-charging-pile","tag-mcb","tag-new-energy","tag-rcbo","tag-type-a"],"metadata":{"_thumbnail_id":["1225"],"themepark_seo_description":["The NDB1LE-63 series of residual current action circuit breakers provide the ground leakage, direct or indirect electric shock by human body and other faults protection, which are applicable to the low -voltage terminal distribution in the industry, civil buildings, energy, communication, infrastructure and other fields. "],"themepark_seo_keyword":["Charging Pile, MCB, RCBO, Type A "],"catce":["sidebar-widgets4"],"views":["1148"],"_dp_original":["1198"],"_edit_lock":["1715420148:1"],"_edit_last":["1"]},"medium_url":"https:\/\/www.sovinelec.com\/wp-content\/uploads\/2024\/05\/RCBO-NDB1LE-63-C63-Type-A-300x300.jpg","thumbnail_url":"https:\/\/www.sovinelec.com\/wp-content\/uploads\/2024\/05\/RCBO-NDB1LE-63-C63-Type-A-150x150.jpg","full_url":"https:\/\/www.sovinelec.com\/wp-content\/uploads\/2024\/05\/RCBO-NDB1LE-63-C63-Type-A.jpg","_links":{"self":[{"href":"https:\/\/www.sovinelec.com\/ru\/wp-json\/wp\/v2\/posts\/1202","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sovinelec.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.sovinelec.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.sovinelec.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sovinelec.com\/ru\/wp-json\/wp\/v2\/comments?post=1202"}],"version-history":[{"count":1,"href":"https:\/\/www.sovinelec.com\/ru\/wp-json\/wp\/v2\/posts\/1202\/revisions"}],"predecessor-version":[{"id":1205,"href":"https:\/\/www.sovinelec.com\/ru\/wp-json\/wp\/v2\/posts\/1202\/revisions\/1205"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sovinelec.com\/ru\/wp-json\/wp\/v2\/media\/1225"}],"wp:attachment":[{"href":"https:\/\/www.sovinelec.com\/ru\/wp-json\/wp\/v2\/media?parent=1202"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sovinelec.com\/ru\/wp-json\/wp\/v2\/categories?post=1202"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sovinelec.com\/ru\/wp-json\/wp\/v2\/tags?post=1202"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}