{"id":644,"date":"2023-05-26T17:13:22","date_gmt":"2023-05-26T09:13:22","guid":{"rendered":"http:\/\/www.sovinelec.com\/?p=644"},"modified":"2023-05-29T09:20:45","modified_gmt":"2023-05-29T01:20:45","slug":"ndq5w-1600","status":"publish","type":"post","link":"https:\/\/www.sovinelec.com\/de\/2023\/05\/26\/ndq5w-1600\/","title":{"rendered":"NDQ5W-1600"},"content":{"rendered":"<section class=\"wp-block-themepark-block-themepark-area block_layout thempark-block undefined\" id=\"\" style=\"\" data-swiper-parallax=\"-700\"><div class=\"block_layout_in\" style=\"\">\n<div class=\"wp-block-column block_layout_in is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"http:\/\/www.sovinelec.com\/wp-content\/uploads\/2023\/05\/NDQ5W-1600.jpg\" alt=\"\" class=\"wp-image-645\" srcset=\"https:\/\/www.sovinelec.com\/wp-content\/uploads\/2023\/05\/NDQ5W-1600.jpg 800w, https:\/\/www.sovinelec.com\/wp-content\/uploads\/2023\/05\/NDQ5W-1600-300x300.jpg 300w, https:\/\/www.sovinelec.com\/wp-content\/uploads\/2023\/05\/NDQ5W-1600-150x150.jpg 150w, https:\/\/www.sovinelec.com\/wp-content\/uploads\/2023\/05\/NDQ5W-1600-768x768.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n<\/div>\n\n\n<div class=\"wp-block-themepark-block-themepark-wright content-super-p\" style=\"font-size:12px;line-height:20px;padding:10px 10px;\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\">1. Applicable Scope and Purpose<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The NDQ5W-1600 automatic transfer switching equipment can be applied to the power distribution system with the AC 50Hz\/60Hz, the rated working current of 200A~1600A, the rated insulation voltage of 1000 V, the rated working voltage of AC415V and below for automatically disconnecting from one power supply and connecting to another power supply. The NDQ5W-1600 automatic transfer switching equipment not only provides<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">the dual power transfer system, but also provides the triple power transfer system and incoming power transfer&nbsp;system of \u201cTwo lines plus bus connection\u201d. Besides the conventional transfer, it also provides the parallel transfer&nbsp;function, thus comprehensively guaranteeing the uninterrupted power supply at special occasions as well as safety<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">and reliability of the load power supply.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This product complies with GB14048.1-2012, GB14048.2-2008, GB\/T14048.11-2016, IEC 60947-1:2011,&nbsp;IEC 60947-2:2006, and IEC 60947-6-1:2013.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2. Specification and Model Description<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ND Q 5 &nbsp;W &#8211; \u25a1&nbsp;\u25a1&nbsp;\/ \u25a1\u25a1\u25a1&nbsp;\/ \u25a1&nbsp;\/ \u25a1&nbsp;\/ \u25a1<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">1&nbsp;&nbsp;2&nbsp;&nbsp;3 &nbsp;4 &nbsp;5 &nbsp;&nbsp;6 &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;7 &nbsp;&nbsp;&nbsp;&nbsp;8 &nbsp;&nbsp;&nbsp;9 &nbsp;&nbsp;10<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">SN &nbsp;&nbsp;&nbsp;SN name&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;NDQ5W<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">1 &nbsp;&nbsp;&nbsp;&nbsp;Enterprise code&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;ND: brand low-voltage electrical appliance<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2 &nbsp;&nbsp;&nbsp;&nbsp;Product code &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Q: ATSE<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3 &nbsp;&nbsp;&nbsp;&nbsp;Design SN &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;5&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4 &nbsp;&nbsp;&nbsp;&nbsp;Actuating circuit breaker&nbsp;&nbsp;&nbsp;W: NDW3 series air circuit breaker<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">5 &nbsp;&nbsp;&nbsp;&nbsp;Rated current of frame &nbsp;&nbsp;&nbsp;&nbsp;1600A<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">6&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Installation mode of the<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;actuating circuit breaker&nbsp;&nbsp;&nbsp;C: Drawout type<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">7 &nbsp;&nbsp;&nbsp;&nbsp;Rated working current&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;02:200A, 04:400A, 06:630A, 08:800A,<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;10:1000A, 12:1250A, 16:1600A<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">8 &nbsp;&nbsp;&nbsp;&nbsp;Number of poles &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;3&nbsp;: 3P; 4: 4P<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">9 &nbsp;&nbsp;&nbsp;&nbsp;Rated working voltage&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;K1: AC380\/400\/415V (TT\/TN),<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;K2: AC380\/400\/415V (IT),<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">10&nbsp;&nbsp;&nbsp;Controller type&nbsp;(Related<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;to the No. 7&nbsp;selection,)&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2L: Dual power transfer<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;3L: Triple power transfer<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;QL: Two lines plus bus connection transfer<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2LB: Dual power transfer with the manual&nbsp;parallel operation&nbsp;function<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;3LB: Triple power transfer with the manual parallel operation&nbsp;function<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;QLB: Two lines plus bus connection transfer with the manual<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;parallel operation function<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Example and description: Choose the same or different rated current in the same frame; consult the after-sales&nbsp;engineer.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">1. NDQ5W-1600 C\/40 \/4\/K1\/2L (one type is possible for the same rated current)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2. NDQ5W-1600 C\/25 32 40\/4\/K1\/3L (different types shall be indicated separately for the different rated<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">current)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4. Main Technical Parameters<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Rated working voltage Ue: AC380\/400\/415V;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Rated control supply voltage of controller Us: TT\/TN system: AC230V; IT system: AC380V;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Rated frequency: 50\/60Hz<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Rated insulation voltage Ui: AC1000V<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Rated impulse withstand voltage Uimp: 12kV<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Utilization category: AC-33iB<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Electrical equipment level: Level CB<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Rated short-circuit breaking capacity Icn: 55kA<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Rated short circuit making capacity Icm (peak value): 121kA<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Rated short time withstand current Icw (effective value): 50kA , 1s<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Contact switching time: 200ms<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Electrical life: 6,500 times<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mechanical life: 15,000 times (free maintenance) 30,000 times (with maintenance)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Isolating function: Available<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div><div class=\"layout_badh\"><\/div><\/section>","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":1286,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"100%","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":true,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":true,"_geo_short_summary":"","_geo_structured_desc":"","_geo_faqs":"","_geo_key_points":"","_geo_target_audience":"","_geo_content_type":"","_geo_last_modified":"","_geo_version":0,"themepark_seo_title":"","themepark_seo_description":"","footnotes":""},"categories":[5,2],"tags":[],"class_list":["post-644","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-znxx","category-product"],"metadata":{"_edit_lock":["1685323245:1"],"themepark_post_width":["100%"],"themepark_post_img":[""],"themepark_post_img_re":[""],"themepark_post_img_cover":[""],"themepark_post_img_fixed":[""],"themepark_post_hide_title":["1"],"themepark_paddingblock":["1"],"_edit_last":["1"],"catce":["sidebar-widgets4"],"themepark_seo_title":[""],"themepark_seo_description":[""],"themepark_seo_keyword":[""],"_thumbnail_id":["1286"],"views":["1198"]},"medium_url":"https:\/\/www.sovinelec.com\/wp-content\/uploads\/2024\/05\/NDQ5W-1600-300x300.jpg","thumbnail_url":"https:\/\/www.sovinelec.com\/wp-content\/uploads\/2024\/05\/NDQ5W-1600-150x150.jpg","full_url":"https:\/\/www.sovinelec.com\/wp-content\/uploads\/2024\/05\/NDQ5W-1600.jpg","_links":{"self":[{"href":"https:\/\/www.sovinelec.com\/de\/wp-json\/wp\/v2\/posts\/644","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sovinelec.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.sovinelec.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.sovinelec.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sovinelec.com\/de\/wp-json\/wp\/v2\/comments?post=644"}],"version-history":[{"count":1,"href":"https:\/\/www.sovinelec.com\/de\/wp-json\/wp\/v2\/posts\/644\/revisions"}],"predecessor-version":[{"id":646,"href":"https:\/\/www.sovinelec.com\/de\/wp-json\/wp\/v2\/posts\/644\/revisions\/646"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sovinelec.com\/de\/wp-json\/wp\/v2\/media\/1286"}],"wp:attachment":[{"href":"https:\/\/www.sovinelec.com\/de\/wp-json\/wp\/v2\/media?parent=644"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sovinelec.com\/de\/wp-json\/wp\/v2\/categories?post=644"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sovinelec.com\/de\/wp-json\/wp\/v2\/tags?post=644"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}